2.4.0.180

Main changes in the version 2.4 comparing to the version 2.3

* LOD, LOQ - the possibility to set the limits of detection and limits of quantification in the calibration window. The exceeding of the limits can be displayed in the result table

* Suggest Global Threshold and Suggest Global PeakWidth functions for easier integration

* Direct printing to PDF format

* The sequence has been extended by the possibility to select PostRun functions for each row separately

* Retention (Kovats) indexes

* Fast browsing through chromatograms from current folder (toolbar and shortcuts)

* Clarity always requires the protective key - dongle (USB or LPT port). The software number (User Code) does not have to correspond to the number of the A/D converter

* The possibility to use the station without User Code - the station will work 30 days or 100 sessions (whatever comes first)


Minor changes:

* Open Chromatogram dialog extended by info about applied electronic signatures

* Automatic FFT filter

* The Digital Output Control dialog now displays the state of the relay contact visually

* Optimized speed of the sequence table pre-run check

* Reports can print full path or relative path to the files

* Reports can print GLP information - version, PC, User

* The zooming on CTRL + Mouse wheel now conforms to MS Windows standards

* Clone and Save As Calibration commands have been extended by the option to erase all responses

* If the external calibration file cannot be found while opening the chromatogram, stored calibration will be offered instead

* Improved and extended text import of chromatograms

* Extended possibility to abort the running sequence - either immediately or after the current sample measurement will finish

* Interactive chromatogram modifications were extended by a more detailed status line and by optional balloon tool tips on the cursor

* Possibility to set the detector names also in single detector chromatograms

* Settable length of history in Recalibration mode i.e. variable floating average

* Export of Result Table extended by User columns


Fixed Bugs:

# Fixed Bug: While editing number in the table a value rounded to specified number of decimal places was offered instead of the complete value

# Fixed Bug: the report styles were not copied to the Common folder during Restore Project

# Fixed Bug: Custom calculations and formulas did not accept the decimal sign (dot)

# Fixed Bug: The Archive and Restore functions did not support the SST methods

# Fixed Bug: The SST event - Run External Program was under certain conditions performed more than once

# Fixed Bug: The SST event - Run External Program was under certain conditions performed incorrectly

# Fixed Bug: When attempting to re-open currently opened SST method, there was not any dialog asking for further proceeding

# Fixed Bug: The residuum of calibration curves was not included in the printed reports

# Fixed Bug: Calibration - Clear All Levels in the Calibration window (tab of the compound) under certain conditions erased only amount and the number of recalibrations but not the responses

# Fixed Bug: The printouts in Win9x were always B&W also on color printers

# Fixed Bug: SST Table always printed the first signal without regard which signal is currently active