*New: Extension MS: Evaluation module - development state.
*New: Localization - option to switch Clarity to different Languages (Spanish, French, Russian, Chinese). German localization can be purchased separately from Techlab company.
*New: Manual control of gradient during run for preparative chromatography now includes: 1. Hold (Resume) - will keep the current gradient conditions until Resume. 2. Manual Flow - allows editing of the gradient table, after OK it will be applied for the rest of the run. Supported only for selected pumps. The actually performed gradient will be stored in the measured chromatogram.
*New: Calibration: Multiple ISTD calculations - up to 5 internal standards supported.
*New: Control AS: CTC-PAL - support for state recording by commdrv.ini on Com port.
*New: Control AS: HTA HT2x00H headspace samplers is available for Testing.
*New: Control DET: New control module YL Instruments RI 2012 refractometric detector.
*New: Control FC: Fraction Collectors - maximum acceptable time value in fraction table increased from 999 to 9999 minutes.
*New: Control FC: Teledyne Isco Foxy Jr. by UNI-RUBY script available for Testing.
*New: Control GC: Dani Master GC now includes new USB driver.
*New: Control LC: Knauer drivers updated to version 3.0.7.3085.
*New: Control LC: New control drivers for Rigol L-3000 HPLC system and L-3320 Autosampler.
*New: Control LC: New control drivers for Rigol L-3000 HPLC system and L-3320 Autosampler.
*New: Control LC: New SISw - Systec Degasser Watchdog (USB Accessory to check Vacuum level by UNI RUBY script) available.
*New: Control LC: New SISw - LC Monitor (USB pH monitor by UNI RUBY script) available.
*New: Control LC: New SISw - USB SSI Pump Interface (USB interface for SSI pumps by UNI RUBY script) available.
*New: Control: Agilent ICF libraries updated to version 1.01.05 SP1.
*New: Data Acquisition: new icon Send Method for Data Acquisition and Device Monitor windows. (Hidden in the default desktop, can be revealed by the Customize command.)
*New: Extension SST: double click in the SST table will activate the respective chromatogram in graph pane.
*New: Chromatogram: Improved File Open dialog for Import/Export.
*New: Chromatogram: Improved import of chromatograms.
*New: Chromatogram: The number of available signals in chromatogram has been increased from 12 to 16.
*New: Installation: the options (Typical, Custom, Full) selected during installation are remembered during updates or reinstallations.
*New: System Configuration: new Instrument type LC-MS and GC-MS.
*New: Wait dialog is now displayed during lengthy operations.
#Fixed Bug: Calibration: Curve Fit Type, possible crash when switching from Sigmoid to Ln or Hyperbolic.
#Fixed Bug: Calibration: Incorrect results if the ISTD peak was referenced by Calculate By and the ISTD amount in calibration was different from 1.
#Fixed Bug: Calibration: Weighing - Weight parameter was not restricted to valid range from 0 to 1.
#Fixed Bug: Control AS: Cetac ASX-8000 the injection valve positions were inverted.
#Fixed Bug: Control AS: HTA HT200H AS-Oven and Syringe temperature settings now accept values 0 (= Off) and from 40 to 150 (Oven) or 170 (Syringe).
#Fixed Bug: Control AS: HTA HT300LV wrong limits for syringe speed.
#Fixed Bug: Control AS: Spark Alias, Method Setup, Input Outputs problem in values editing.
#Fixed Bug: Control DET: Shodex RI 10x Detector (detectors by UNI-RUBY) - incorrect Signal Axis name and units displayed before method sending.
#Fixed Bug: Control FC: Fraction collectors by UNI-Ruby - waste was not set in case of pump error.
#Fixed Bug: Control FC: VICI valve as Fraction Collector was not going to waste after exceeding maximum position.
#Fixed Bug: Control GC: Agilent 7890 - display of valve 7 and 8 state in the Device Monitor window.
#Fixed Bug: Control GC: Agilent 7890 - problem in data acquisition from two instruments on the same station.
#Fixed Bug: Control GC: Agilent 7890 GC - crash due to memory leaks in case the system was idle for long time.
#Fixed Bug: Control GC: Agilent 7890 GC - Reference Flow checkbox state incorrectly handled.
#Fixed Bug: Control GC: Agilent 7890 GC Method setup, Temperature values are now checked against set Oven Max Temperature.
#Fixed Bug: Control HW: The default new method for DataApex converters now sets range to 1250 mV (in version 4.0 it was 10000 mV).
#Fixed Bug: Data Acquisition window, incorrect display of signal for time higher than 300 min (last 300 min of data were displayed repeatedly).
#Fixed Bug: Extension GPC: The peak coloring is now functional also in GPC Extension.
#Fixed Bug: Chromatogram, Integration table, sorting is now disabled.
#Fixed Bug: Chromatogram: Mathematics, Differentiate caused signal offsets in some situations.
#Fixed Bug: Chromatogram: Peak Area coloring was incorrect when baseline crossing was allowed.
#Fixed Bug: Sendcom.exe did not support COM port numbers over COM9.