*New: Control: Advion Expression CMS - API updated to version 2.2.29.2.
*New: Control: Antec Decade Elite detector control module has been released.
*New: Control: Antec Decade II and Decade Elite new Cell Off button in Device Monitor. Detector is not providing any data when cell is off.
*New: Control: Dani Master updated drivers: GC to 1.5.12.0 version, DHS to 1.0.9.0 version and SHS to 1.0.11.0 version.
*New: Control: Ellutia series 200 GC driver updated to version 1.0.2.4.
*New: Control: GCxGC modulator prototype is available in testing state.
*New: Control: HTA HT2000H and HT2100H autosamplers support higher oven and syringe temperatures (Firmware 1.12 and higher).
*New: Control: HTA HT4000L - updated control module.
*New: Control: LaChrom Elite autosampler - new Wash dialog button in the Device monitor.
*New: Control: Microsaic 4000 MiD mass spectrometric detector is available in testing state.
*New: Control: Sedere Sedex LC and FP detectors - new commands for standby mode implemented.
*New: Control: Shimadzu GC 2010 - support for temperature program settings for PTV/OCI inlet.
*New: Control: Shimadzu SIL-20ACHT autosampler control module has been released.
*New: Control: Schambeck RI2012 refractive index detector by UNI-Ruby script released.
*New: Control: Spark Alias - LAN communication mode changed from UDP to TCP. Note the used communication mode needs to be changed by the Alias Service Manager.
*New: Control: Spark Integrity autosampler is available for testing.
*New: Control: YL 6500 GC driver has been updated to version 1.0.1.6.
*New: Device Monitor, LC Gradient, Purge Dialogue - new field Max Pressure to limit the current maximum pressure value. Prefilled with value from current method.
*New: Extension PDA: PDA Window - Isoplot view - at opening the cursor will be always centred (regardless of previous position at closing the window).
*New: User Accounts - new option Start Acquisition.
#Fixed Bug: Calibration - Not calculated results for dual signal chromatogram when a separate ISTD compound was used on each signal.
#Fixed Bug: Calibration window - wrong assignment of the 13th icon on the signal toolbar.
#Fixed Bug: Control: Sequence with controlled sampler - when the sequence was stopped by missing vial, after changing the vial number and resume it attempted to use the original vial.
#Fixed Bug: Control: Shimadzu AOC-20i - wrong tray autodetection.
#Fixed Bug: Control: Shimadzu GC 2010 - Sending Method to one GC 2010 may cause communication error on other GC 2010 instrument.
#Fixed Bug: Control: Schambeck RI2012 detector - possible communication error by during start by external input.
#Fixed Bug: Extension CE: CE instrument type, in toolbars the Chromatogram was not replaced with Electropherogram.
#Fixed Bug: Extension GPC: Summary table on GPC Instrument displayed GPC mode columns also when switched to standard mode.
#Fixed Bug: Extension MS: Missing scan_index parameter in Export MS to AIA format.
#Fixed Bug: Extension PDA: Possible crash when opening freshly acquired chromatogram in PDA window in some situations.
#Fixed Bug: Fixed possible crash during restore projects to a newly created directories.
#Fixed Bug: Chromatogram - Front Tangent and Tail Tangent operations were not functional on negative peaks.
#Fixed Bug: Chromatogram - Change in Sample or Sample ID is now propagated to summary table immediately.
#Fixed Bug: Chromatogram - Mathematical operations used incorrect sample rates.
#Fixed Bug: Chromatogram - Possible crash when pressing Ctrl+E (Export Chromatogram).
#Fixed Bug: Chromatogram - Upon closing multisignal chromatograms with disabled signals in overlay, wrong signal may have been activated.
#Fixed Bug: Chromatogram window on first instrument, zoom has been reset when View Calibration button was used.
#Fixed Bug: Reports - Print issues for landscape mode.
#Fixed Bug: Reports - Problems with setting the Modified date in reports.