7.4.0

*New: Control: Released - Knauer AS 6.1L autosampler control module has been released.

*New: Control: Released - YL Instruments YL9900 MS detector has been released.

*New: Control: Testing - Spark SPH1299 pump control module is available for testing.

*New: Control: Updated drivers - Advion CMS API updated to version 4.0.13.8.

*New: Control: Updated drivers - Agilent ICF libraries updated to version A.02.04.DU1.

*New: Control: Updated drivers - Knauer drivers updated to version 7.04.000.5053.

*New: Control: Agilent ICF - listing of ICF modules in the Available control modules has been reorganized.

*New: Control: Agilent ICF control is no longer supported in Windows XP and Windows Vista.

*New: Control: Agilent ICF for GC - configurations that include Agilent GC modules from Clarity 7.3 or older must be reconfigured in Clarity 7.4, due to revised ICF installation system.

*New: Control: Knauer control modules - all of the drivers are now displayed under a single item in the installer. It is no longer possible to install only a single selected driver.

*New: Control: Knauer drivers for Fraction Collectors are now available, Knauer FRC option is necessary. Contact directly Knauer company to purchase respective license.

*New: Control: Shimadzu GC2011/2014 - values of the detector gas flows have been added to the Device Monitor.

*New: Calibration: new option to add compounds on All signals/Active signal only. It effects on which signal(s) the compounds will be calibrated and on which signal(s) the Used column will be checked.

*New: Calibration: Uniqueness of compound retention time will be checked per signal, not in the entire calibration as before.

*New: Extension CE: The Column Length item has been removed from the User columns on the CE Instrument.

*New: Extension EA: Method Setup - Measurement tab now includes amended description of items.

*New: Extension EA: Sample Amount column in the Sequence has been renamed to Sample Weight.

*New: Extension GPC: Support for export to *.dbf format for Ranges and Slice Tables, support for export of tables in WYSIWYG format. The Export of Result table in Fixed format has been left unchanged for compatibility reasons.

*New: GLP: Audit trail - closing a chromatogram in the Chromatogram window is now recorded.

*New: GLP: Audit trail - changes in the PDA method are now  recorded.

*New: GLP: Audit trail - the Station Audit Trail now records the creation of new Sequence and Calibration.

*New: GLP: The Ask for Reason of File Change function is now  applied also for changes in the System Configuration.

*New: GUI: Device Monitor window is now resizable (set the "Fit to content" option to "Off").

*New: GUI: The Graph Properties dialog is now resizable.

*New: GUI: Verify Signatures dialog window is now resizable.

*New: Import & Export: Improved behavior of Preset during Import Chromatogram.

*New: Import & Export: Support for Y axis name in chromatogram is now available for import/export of ASCII files.

*New: Other: Improved protection against invalid filenames and paths (length, invalid characters, etc.).

*New: Other: Method Setup - Event table now supports variables for Sample (%q), Sample ID (%Q),  Chromatogram (%K), Method (%J), Sequence (%s), Vial Number (%v) and Injection number (%i) as parameters for external programs.

*New: Sequence: Fill series improved behavior for alphanumeric Vial numbering.

#Fixed Bug: Control: Agilent 6890 GC not detected S/SL inlet for some instruments (introduced in 7.3).

#Fixed Bug: Control: Agilent ICF control 7890 - Clarity inactive after finishing run for 30-60 sec.

#Fixed Bug: Control: Agilent ICF GC control - incorrect name of the Y axis (units instead of value).

#Fixed Bug: Control: R-Biopharm RIDACREST control module - fixed possible crashes.

#Fixed Bug: Control: Sedere Sedex 100 chromatogram signal displayed with wrong time axis (3x shorter).

#Fixed Bug: Control: Shimadzu 2010/2014 GC - fixed possible communication errors.

#Fixed Bug: Control: UNI-RUBY pumps - problems with disabled solvents in Method Setup - LC Gradient table Options.

#Fixed Bug: Spark Mistral - sequence interrupted due to a false Low Fan Speed error.

#Fixed Bug: Calibration: the commands to transfer values from standard to calibration were active even in case the selected signal was not available in the standard, now they will be inactive.

#Fixed Bug: Extension GPC: fixed problems in exports.

#Fixed Bug: Extension MS: Attempt to perform MS search without selected MS spectral library resulted in freeze. Search button is now disabled when no library is selected.

#Fixed Bug: Extension MS: Conformity was displayed for peaks with no matching spectrum in library.

#Fixed Bug: Extension MS: Incorrect selection of quantification signal in the MS Method Table.

#Fixed Bug: Extension PDA: Displayed wrong active signal from a chromatogram when subtraction chromatogram was used. May have crashed when subtraction chromatogram was not available.

#Fixed Bug: Extension SST: The SST data for last peak were not displayed for ISTD calculation with Hide ISTD peak active.

#Fixed Bug: GLP: Audit trail - when a new location for audit trails was defined, part of the actions was still logged to the audit trails in the default location.

#Fixed Bug: GLP: User Accounts - import chromatogram was not allowed for user with denied Edit Chromatogram privilege.

#Fixed Bug: GLP: User Accounts - User with denied Edit Calibration option was able to change the Is ISTD and Use ISTD options.

#Fixed Bug: GUI: System, Configuration, values in columns S/N and From were not displayed in certain localizations (German, Russian, ...)

#Fixed Bug: GUI: User columns in the Summary Table were incorrectly displayed (introduced in 7.3).

#Fixed Bug: Chromatogram: Chromatogram may not have been created if row in the sequence is set to Standard type - Blank and the used method does not have a calibration defined.

#Fixed Bug: Import & Export: Fixed possible issues with import of chromatograms created by CSW32.

#Fixed Bug: Import & Export: Changes in format of table headers - names and units are now on the same row.

#Fixed Bug: Import & Export: The sequence import function incorrectly checked the "Include in SST" option.

#Fixed Bug: Stability: Cannot Create Temporary Files Error due to impossibility to create directory for temporary files.

#Fixed Bug: Stability: Crash when opening CSW32 chromatograms (introduced in 7.3).

#Fixed Bug: Stability: Possible crash during damaged *.cdf file import.

#Fixed Bug: Stability: Possible crash when opening PDA chromatogram in PDA window with fixed axis set.

#Fixed Bug: Stability: Possible crash while printing Result Table with defined user columns and the user column is using values calculated by the column next to the right from it.

Product Line
Product Version
7.0
Released