*New: Control: Released - HTA HT1500L autosampler control module has been released.
*New: Control: Released - Microsaic 4500 MiD control module has been released.
*New: Control: Released - Rheodyne - FC by MX series II multiposition valve control module has been released.
*New: Control: Testing - Ecom Toy18 and Baby18 control modules are available for testing.
*New: Control: Testing - Flom UI-22 control module is available for testing.
*New: Control: Testing - Jai FC-7000 control module is available for testing.
*New: Control: Testing - Knauer distributed control modules for Bronkhorst Cori-Flow flowmeter and Labomatic Labocol Vario-4000 Fraction Collector are available for testing.
*New: Control: Testing - PrinCE Next CE capillary electrophoresis and PrinCE Next DAD detector control modules are available for testing.
*New: Control: Testing - Unimicro ColumnOven control module is available for testing.
*New: Control: Testing - Unimicro HVPS control module is available for testing.
*New: Control: Testing - VICI Valco Fast Temperature Programmer control module is available for testing.
*New: Control: Updated drivers - CTC-PAL control - default cycles and configuration were updated.
*New: Control: Updated drivers - CTC-PAL3 driver has been updated to version 1.1.0.23.
*New: Control: Updated drivers - ECOM ECD2000 to 3.5.0.0, Panda30HID to 2.0.0.0, Toy to 1.8.0.0, ECDA2000 to 2.5.0.0, ECF2000 to 1.7.0.0, ECP2000 to 3.5.0.0 and ECO2000 to 2.9.0.0.
*New: Control: Updated drivers - Elysia GabiNova driver has been updated to version 1.0.7.0.
*New: Control: Updated drivers - Elysia GabiStar driver updated to version 1.0.9.0.
*New: Control: Updated drivers - Elysia RamonaStar driver has been updated to version 1.0.5.0.
*New: Control: Updated drivers - Knauer HPLC drivers updated to version 8.1.0.6018.
*New: Control: Updated drivers - YL Instruments YL9150Plus driver has been updated to version 1.0.0.4.
*New: Control: GL Science LC800 control module removed from installation.
*New: Extension MS: Automatic Compound Search in MS Search now lists more than one hit at each retention time.
*New: Extension MS: New Search button for selecting Interval/Background Subtraction interval directly from the chromatogram.
*New: Chromatogram: Import chromatogram (text format) added new column for signal name.
*New: Installation: Clarity does not allow to use unauthorized control modules anymore. Any configured unauthorized control module will be automatically removed from the configured Instrument.
*New: Main window: Check for update dialog pops up when a newer version is available.
*New: Main window: Information about Instrument status was added into the Main window.
*New: Method: New entries in others.ini file to define threshold for individual auxiliary signals, decimal values are now accepted. These entries affect Event Table commands - see Help for more information.
*New: Method: Snapshot command was added into the Event Table commands.
*New: Other: TeamViewer QS (tool for online support) has been updated to version 14.2.
*New: Printing: Preview image for Header in the Report Setup.
#Fixed Bug: Audit Trail: Corrupted or missing audit trail during measurement was not automatically replaced by a new audit trail.
#Fixed Bug: Calibration: Size of splitter view was not remembered on a compound tab.
#Fixed Bug: Control: Agilent ICF - fixed problem in performing the Sequence mode for headspace samplers.
#Fixed Bug: Control: Agilent ICF - Problems in auxiliary signals synchronization.
#Fixed Bug: Control: Agilent ICF control modules - possible wrong conversion of units for Auxiliary signals.
#Fixed Bug: Control: Agilent ICF LC control - missing units in method parameters in report.
#Fixed Bug: Control: CTC-PAL - some buttons in the Method Setup were hidden until revealed by mouse cursor.
#Fixed Bug: Control: CTC-PAL3 possible crash while attempting to display graphical tray while ICF LC drivers are not installed (8.1 version only).
#Fixed Bug: Control: Error in UNI-RUBY ExampleKnauerSmartLine1000pump.rb example script in reporting inverted order of partial flows to device monitor.
#Fixed Bug: Control: Rheodyne MX II valve - error in sending position 10 and higher.
#Fixed Bug: Control: Sedere ELSD detectors - in case of failed auto detection on first attempt, any subsequent attempts failed and Clarity had to be restarted.
#Fixed Bug: Control: Sedere ELSD detectors - wrong time axis in chromatogram.
#Fixed Bug: Control: Spark Alias sampler - possible communication error on LAN communication.
#Fixed Bug: Control: Teledyne Isco Foxy 200 fraction collector - some positions in rack were not be accessible in firmware version M (CombiFlash).
#Fixed Bug: Data Acquisition: Noise readout showed non-actual values in case detector did not provide any signal data.
#Fixed Bug: Extension CE: Chromatogram label was incorrectly displayed instead of Electropherogram.
#Fixed Bug: Extension GPC: Slice table with user columns was not printed correctly.
#Fixed Bug: Extension GPC: Wrong evaluation of MW averages when Integration operation Baseline Crossing was used.
#Fixed Bug: Extension MS: Peak Name tags were not displayed on the quantification signal.
#Fixed Bug: Chromatogram: Integration table did not refresh correctly after some operation changes (only after closing and opening the chromatogram).
#Fixed Bug: Chromatogram: Position of Peak toolbar in the Chromatogram window was not stored correctly.
#Fixed Bug: Chromatogram: User Columns, special values First and Last were related to row order and not to peak order.
#Fixed Bug: Method: Event table not reacting to auxiliary signals when limits were below 1.
#Fixed Bug: Method: Problem with method file names containing dot in the middle.
#Fixed Bug: Method: Units field length was not unified across Clarity - now it is limited to 10 characters.
#Fixed Bug: Method: Wrong temperature units stored in Chromatogram Event Table for auxiliary signals.
#Fixed Bug: Other: Sendcom.exe utility communication problems on MultiCom.
#Fixed Bug: Printing: Result Table and All Signals Results Table printed in wrong position.
#Fixed Bug: Printing: Standard vial numbers were printed even though sequence row contained alphanumeric vial display.
#Fixed Bug: Printing: Wrong default filename for Print to PDF from Chromatogram window (introduced in 8.1.0.).