5.0.1

*New: Clarity2Go - improved "Clarity2Go Configuration" window.
*New: Clarity2Go - support for proxy server setting in Clarity2Go Configuration / Advanced dialog.
*New: Control AS: CTC-PAL  GC_Inj and HS_Inj cycles were updated. Older methods using those cycles need to be recreated.
*New: Control AS: Ecom AS-54 control discontinued.
*New: Control AS: Spark Alias: new service functions in Device Monitor.
*New: Control DET: Advion Expression CMS detector control module is now available for testing.
*New: Control FC: Advantec Fraction Collector CHF122SC control module available.
*New: Control GC: Ample Technology Center 6900 GC control module available.
*New: Control GC: DANI drivers updated Master GC to version 1.4.6.5,  Master SHS to version 1.0.1.1., Master DHS to version 1.0.3.1.
*New: Control LC: Agilent ICF Control module is now available, some devices are still in testing state (consult the D004 datasheet to see which are testing/released).
*New: Control LC: ASI Pumps 500, 501 and 520 control module available.
*New: Control LC: Ecom Iota-S-10 and  Kappa10PP Control module available.
*New: Control LC: Rheodyne LabPro Valve by Ruby control module is now available for testing.
*New: Control LC: Rigol drivers updated. The L-3300 to version 1.0.0.24 and L-3320 to version 1.0.0.17.
*New: Control: ECOM new control modules ECD2000 Series - ECD2800 detector, ECP2000 Series - ECP2010, ECP2050, ECP2002 pumps, ECO2000 Series - ECO2080 column oven. ECOM drivers updated Flash 12 DAD detector to version 1.1.1.0., Ecom Iota pump  to version 1.0.4.0, Flash 06 Single detector to version 1.1.1.0.
*New: Control: Ingos AAA500 driver updated to version 1.0.2.0.
#Fixed bug: Acquisition: In start-restart mode the autostop time was not reset at restart and the next acquisition ended prematurely. Affected only some detectors.
#Fixed bug: Multiple ISTD: Compound assignement to ISTD2-5 was not saved in calibration.
#Fixed Bug: Audit Trail: Some errors were not correctly recorded in Daily Audit Trail.
#Fixed Bug: Batch Sequence reprocess - the Injection Volume incorrectly converted from ul to ml.
#Fixed Bug: Control AS: CTC-PAL - sending method to sampler during the loading of configuration caused communication deadlock.
#Fixed Bug: Control AS: CTC-PAL communication over LAN.
#Fixed Bug: Control AS: HTA HT2000H - vials above 14 caused invalid method error.
#Fixed Bug: Control AS: HTA HT2x00H sampler - wrong Fill Speed and Injection Speed valid values range check.
#Fixed Bug: Control AS: Sykam S5200 autosampler:  injection volume from sequence was ignored, zero volume injected instead. Bug introduced in 5.0.0.323 version.
#Fixed Bug: Control FC: Foxy Jr. and Foxy Rx - rack was not possible to be defined manually.
#Fixed Bug: Control GC: Agilent 5890 and selected other controlled detectors - the signals disabled in method were incorrectly enabled after upgrade to 5.0.0.323 version.
#Fixed Bug: Control GC: Agilent 6890 - the GC control was not functional in case no detector was configured.
#Fixed Bug: Control GC: Agilent 7890 - possible freeze at Clarity closing.
#Fixed Bug: Control GC: Agilent 7890 - rounding of parameters during loading method from GC ( From GC command) on computers with non-US locales setting (introduced in 5.0.0.323).
#Fixed Bug: Control GC: Agilent 7890 - when using ramped pressure in method, the GC stayed in Control state for excessive time.
#Fixed Bug: Control LC: Agilent ICF - detector signal names may have included wavelength info on some detectors, when comma was set as decimal separator.
#Fixed Bug: Control LC: Agilent ICF control - memory leaks upon displaying the ICF property pages in method setup causing erratic behavior.
#Fixed Bug: Control LC: Agilent ICF control - sending/loading method failed when system did not include any detector.
#Fixed Bug: Extension PDA: Chromatogram - Result table - the Best Match and Best Match Name columns were not displayed for uncalibrated calculations.
#Fixed Bug: OQ Validation: the RSD% limits for Area and Height  in ISTD calculation were adjusted to better reflect the expected spread of values on different acquisition ranges.
#Fixed Bug: Sequence import - missing support for ISTD2 - ISTD5 columns.