*New: Bunching of data points is now separated from the Peak Width parameter. Bunching indicates the number of data points to be averaged. Default value for new methods is 1; valid range is 1-250. Old chromatograms will open with the bunching value that has been set automatically by the previous algorithm. See the detailed explanation in reference help or in M195 - Clarity 6.0 vs 5.0 manual.
*New: Calibration: changed behavior of the Update Retention Time option - now the selected action is performed unconditionally.
*New: Calibration: ISTD calculation could be now used for unidentified peaks (quantitated by response factor).
*New: Calibration: option to disable individual recalibrations on the same level in Show Details (former Show History) window.
*New: Calibration: option to disable warning about standard chromatogram reuse.
*New: Calibration: redesigned dialog for manual calibration/recalibration.
*New: Calibration: the Calibrate, Add peak option will now add all peaks from one standard chromatogram to the first shared empty level.
*New: Calibration: the Update Calibration Response option in Calibration Options dialog used for response correction based on injection volume has been removed.
*New: Configuration: Instrument Type selection was changed to dialog window.
*New: Control: Advion Expresion CMS - 6 tuning ions are now supported.
*New: Control: Agilent ICF control libraries updated to version A.02.02.
*New: Control: Dani Master GC driver updated to version 1.15.11.0 and Master TOF driver updated to version 1.0.7.0.
*New: Control: Dani Master TOF mass spectral detector control module has been released.
*New: Control: ERC - Refractomax 520 series control module is available in testing state.
*New: Control: GCxGC modulator control module available for testing in development state.
*New: Control: GL Sciences LC 800 HPLC system - drivers updated to version 2.0.1.0.
*New: Control: HTA HT2800T autosampler - control in liquid and headspace mode.
*New: Control: HTA HT3000A and HT3200A - new "Close Tray after Injection" option in the Method Setup dialog.
*New: Control: Knauer drivers updated to version 5.0.5.4110.
*New: Control: Knauer Virtual detector will correctly replay chromatograms with the new (6.0) chromatogram data format. To replay chromatograms from older versions, it is necessary to open them and save first to convert them to the new format.
*New: Control: Kontron 432 control UV/VIS detector control module has been released.
*New: Control: Netel GC Analyte2900/Chromlite3000 - control module available in development state.
*New: Control: Rigol L3000 Driver - update to version 1.0.0.13.
*New: Control: Techlab Minipump1 LC pump control module has been released.
*New: Control: VICI Fraction collector by VICI valve - now supports all communication modes (formerly supported only Legacy Mode 2).
*New: Extension GPC: corrected calculation for the Averaging in Slice Table. Does not affect the result table MW averages.
*New: Extension GPC: the GPC Calibration - Slice table, new option Integral Percentages Increasing/Decreasing with M.
*New: Extension SST: the column Response will be supported.
*New: Chromatogram: rearranged layout of the Graph Properties, specifically the Gradient and Auxiliary tabs.
*New: Chromatogram: Default signal colors were changed in DataAcquisition and Chromatogram windows.
*New: Chromatogram: Graph Properties now includes option to hide/show auxiliary signals individually.
*New: Chromatogram: Result table - Improved speed during user column calculations.
*New: Installation now requires approval of the EULA document.
*New: New chromatogram data format to enable processing of larger data ranges. The chromatogram files are not backward compatible with version 5.0.5 and earlier. Older chromatograms will be automatically converted, the old data will be retained in them. It is possible to save the new chromatograms to old format, however some rounding errors will be introduced.
*New: New look for toolbars, table headers and menu in Clarity windows.
*New: Sequence: option to open chromatograms directly from the Sequence table from the Status column.
*New: Sequence: Improved design of the sequence table for easier orientation in the Sequence table.
*New: Station will not revert to forced (red warning stripe) DEMO mode due to wrong or missing user code or HW key problems.
*New: TeamviewerQS utility updated to version 10
*New: The Save As to old DataApex software formats (CSW17, CSW32) will be no more supported for chromatograms, methods, sequences and calibrations.
*New: User options: the Auxiliary signals and Gradient tabs were united.
#Fixed Bug: Calibration: possible crash when the hyperbolic curve fit was used.
#Fixed Bug: Calibration: problem in handling of last reference peak identification window.
#Fixed Bug: Calibration: the Default Injected Volume in Calibration Options dialog - values used for response correction are now recorded.
#Fixed Bug: Calibration: the Show History option has been renamed to Show Details, similar change also applied in the Report Setup.
#Fixed Bug: Calibration: wrong peak type for ISTD peaks in calibrations imported from old (CSW17) format.
#Fixed Bug: Control: Advion Expression CMS - problem with SIM signals not appearing in chromatogram.
#Fixed Bug: Control: Agilent 7683 AS on 6890 GC - errors in the warning message about acceptable injection volumes when coma was set as decimal separator.
#Fixed Bug: Control: Agilent 7890 - the Post Run time (GC-Oven/Zones) was sent in hours instead of minutes.
#Fixed Bug: Control: Agilent 7890 GC with AS - communication error when sending method with Pulsed Splitless injection mode
#Fixed Bug: Control: Agilent 7890 GC - disabled options for Pulsed Split injection mode.
#Fixed Bug: Control: HTA HT300A sampler - erroneous warning about syringe speed for 10 uL syringe.
#Fixed Bug: Extension DHA: corrected compound assignments to groups.
#Fixed Bug: Chromatogram: the function of dragging chromatogram in the graph using Ctrl and left mouse button was not functional (since version 5.0.4)
#Fixed Bug: Chromatogram: Graph Properties, Signals - wrong units handling in the Signal Offset field.
#Fixed Bug: Chromatogram: the Groups dialog - now checks for validity of the identifier (A-Z) during entry.
#Fixed Bug: Chromatogram: Wrong signal units after mathematical operations (storing one signal from multi signal chromatogram as a separate chromatogram).
#Fixed Bug: Reports: Print Calibration Details - amended column layout was not stored.
#Fixed Bug: Sequence: the Reset Status command is now disabled during sequence run.
#Fixed Bug: Some system files were not found, when the configuration file *.cfg was set by commandline to different directory than the Clarity.exe file.
KNOWN ISSUE: Control module CTC-PAL - unexpected device reset occurs at second injection in the headspace mode.