7.2.0

*New: Control: Released - YL Instruments YL FC1 and YL FC2 fraction collector control modules have been released.

*New: Control: Released - YL Instruments YL2000H, YL2000HT and YL2100H autosampler control module has been released.

*New: Control: Testing - Ecom ECDA2000 PDA detector control module is available for testing.

*New: Control: Testing - Ecom TOY UV/PDA detector control module is available for testing.

*New: Control: Testing - Interlab Omega FLD detector control module is available for testing.

*New: Control: Testing - Shodex RI-501 detector control module is available for testing.

*New: Control: Testing - YL Instruments YL6900 MS detector control module is available for testing.

*New: Control: Updated drivers - DANI Master GC driver updated to version 1.6.2.0.

*New: Control: Updated drivers - Ecom drivers updated - ECD2000 to version 2.4.0.0; ECO2000 to version 2.1.0.0; ECP2000 to version  2.5.0.0; Flash06DAD to version 2.2.0.0; FLASH12DAD to version 2.2.0.0; Iota to version 2.1.0.0

*New: Control: Updated drivers - YL Instruments YL6500GC driver updated to version 1.0.1.6.

*New: Control: PG instruments AS 600 and GC 600 modules no longer supported.

*New: Extension PDA: using the New library in the PDA window will invoke File Save dialog.

*New: GLP: Improved recording of selected operations in audit trail.

*New: GLP: New checkbox "Disallow to Use Unsaved (Modified) Method in the GLP Options dialog.

*New: Chromatogram: Experimental integration algorithm - Improved derivative calculation.

*New: Chromatogram: Experimental integration algorithm - Improved hiding of peaks.

*New: Data Acquisition: Snapshot command was disabled outside run.

*New: Installation: Clarity now requires Service Pack 1 (SP1) to be installed on Windows 7.

*New: Installation: Faster and smoother installation.

*New: Installation: The Sentinel HW key drivers installation was removed from Typical installation.

*New: Other: Clarity.ini configuration file is now no more used, its functionality was moved to Others.ini.

*New: Other: Most critical issues with displaying Clarity on high DPI monitors are now resolved, few issues may still arise.

*New: Printing: Sample Info section in the Report setup  dialog was divided into Sample Description, Sample Parameters and GPC Parameters.

*New: Sequence: Each row of a sequence can now contain comments - measured chromatograms will contain corresponding commentary. By default this column is hidden, display it using Setup Columns.

*New: Single Analysis: the Comments field indicates whether there are any comments without having to open the edit dialog.

#Fixed Bug: Calibration: Clear all levels in calibration is not propagated immediately to a chromatogram

#Fixed Bug: Calibration: column headers colors corrected to properly distinguish signal dependent values

#Fixed Bug: Control: Agilent ICF - method property pages in acquired chromatogram are not displayed (introduced in 7.1.0).

#Fixed Bug: Control: Agilent ICF - Possible crashes in LC control by ICF due to wrong auixiliary signals mapping.

#Fixed Bug: Control: Agilent ICF LC possible crashes due to memory leaks

#Fixed Bug: Control: Agilent ICF LC system - non functional external start by manual valve.

#Fixed Bug: Control: Int9 A/D board initial state of digital outputs was not saved.

#Fixed Bug: Device monitor: incorrect redrawing after changin the order of displayed panels.

#Fixed Bug: Extension MS: fixed bug in Fill all responses in MS Calibration

#Fixed Bug: Extension PDA: The View / Maximimize View command in the menu of the PDA window did not list the available panes correctly.

#Fixed Bug: Chromatogram: Experimental integration algorithm - Fixed bugs in Savitzky-Golay and Moving average filters.

#Fixed Bug: Imports: Non-functional option All x Files during import of multiple text files.

#Fixed Bug: Method Setup: Behavior after editing Template Method opened from Sequence.

#Fixed Bug: Method Setup: Changes in the Measurement tab made during the acquisition will be propagated to the chromatogram.

#Fixed Bug: OQ Wizard: Specififc desktop was not used during validation.

#Fixed Bug: Printing: Problems in printing the Sigmoid calibration curve

#Fixed Bug: Single Analysis: the %n has not been increased after the chromatogram was created due to abort.

#Fixed Bug: Stability: Improvements in preventing crashes, memory leaks and other stability issues.