*New: Control: Released - Fuli GC 9720 Plus control module has been released.
*New: Control: Released - Fuli GC 9790 Plus control module has been released.
*New: Control: Released - JAI FC-7000 control module has been released.
*New: Control: Released - Shimadzu GC2010 Pro control module has been released.
*New: Control: Released - Sykam S6510 valve control module has been released.
*New: Control: Released - VICI Valco TCD3 Thermal Conductivity detector control module has been released.
*New: Control: Released - Watrex Streamline AS1, AS2 and UV1 control modules have been released.
*New: Control: Testing - Agilent 8860, 8890 and Intuvo 9000 GC control modules are available for testing.
*New: Control: Testing - Analytik Jena PQ LC / IC control module is available for testing.
*New: Control: Testing - CQS Climax HPLC system control module is available for testing.
*New: Control: Testing - Esensing MassChrom1299 HPLC system control module is available for testing.
*New: Control: Testing - Futecs CD-6000, CT-6000, P-6000 and RI-6000 control modules are available for testing.
*New: Control: Testing - Jasco FP-4020/4025 control module is available for testing.
*New: Control: Testing - Spark LC1299 and LC1299 Plus HPLC systems control modules are available for testing.
*New: Control: Testing - Sykam S150 control module is available for testing.
*New: Control: Testing - Sykam S4120 control module is available for testing.
*New: Control: Testing - Watrex Streamline CT1 column thermostat control module is available for testing.
*New: Control: Testing - Watrex Streamline IC1 control module is available for testing.
*New: Control: Testing - Watrex Streamline P1m pump control module is available for testing.
*New: Control: Testing - Watrex Streamline P1s pump control module is available for testing.
*New: Control: Testing - Young In Chromass - ChroZen GC control module is available for testing.
*New: Control: Updated drivers - Agilent ICF libraries have been updated to version A.02.06.DU3.
*New: Control: Updated drivers - Dani Master GC driver has been updated to version 1.6.11.0.
*New: Control: Updated drivers - Knauer HPLC drivers updated to version 8.1.0.6036.
*New: Control: Updated drivers - Sykam S1130 driver has been updated to version 2.0.1.5.
*New: Control: Updated drivers - Sykam S5300 driver has been updated to version 2.0.0.13.
*New: Control: Updated drivers - Young In Chromass YL9130 driver has been updated to version 4.0.1.12.
*New: Control: Updated drivers - Young In Chromass YL9150Plus driver has been updated to version 1.0.0.6.
*New: Control: Agilent 1200 (supporting selected DAD and FLD models) was removed from installation. In order to continue using Agilent 1200, please use the Agilent ICF LC driver.
*New: Control: Agilent ICF - changes in the Method Setup are now logged in the Audit Trail.
*New: Control: Antec AS 110 control module was replaced by Alias control module. The functionality remained the same.
*New: Control: Antec Decade Elite - added support for Pulse mode II.
*New: Control: Spark Symbiosis ACE - new options for addressing cartridges.
*New: Control: Vici Valve - option in Setup, Configuration to set selected position on Instrument close (previously part of method).
*New: Audit Trail: AreaEN and DescriptionEN columns are filled even when the station is switched into English.
*New: Audit Trail: Audit Trails created with version 8.3 cannot be opened in previous versions due changes in the internal format.
*New: Calibration: Rearranged layout of Calibration Options.
*New: Calibration: Rearranged layout of detail of a calibration compound.
*New: Calibration: Rec No. parameter in Calibration now shows number of used recalibrations to number of total recalibrations on the level displayed.
*New: Calibration: Weight options in the Calibration Options dialog have been removed. Any existing calibrations with this option are automatically transferred to Average.
*New: Extension MS: Chromatogram window - MS integration item added to MS menu.
*New: GLP: New item "Disallow Chromatogram Merge Operation" in the GLP Options dialog.
*New: Chromatogram: Enabled a limited support for Paste operation into the Integration table.
*New: Chromatogram: Improved Asymmetry calculation.
*New: Installation: Installation step with Hardware Setup with option to select A/D converters to apply predefined configuration was removed.
*New: IQ: Reorganized IQ to better distinguish between control modules installed by Clarity and by 3rd parties.
*New: Method: Added support for versioning of method file (*.met).
*New: OQ Validation: Instead of Knauer Virtual Detector a new OQ Validation detector by Ruby script is used.
*New: Other: Removed echotool.exe from the installation. For further use it can be downloaded from the internet.
#Fixed Bug: Control: Agilent 1260 G5667A - incorrect mapping of tray.
#Fixed Bug: Control: Agilent 5890 GC - chromatogram contains less data points than expected (introduced in 8.2.0 due to error in reading data from GC).
#Fixed Bug: Control: Agilent ICF - "Error while unloading appdomain" in configuration, setup, tray configuration on computer with touch screen.
#Fixed Bug: Control: Agilent ICF GC - Invalid vial position for tray used with AS7693.
#Fixed Bug: Control: Agilent ICF GC - Method print report improved layout by including sections.
#Fixed Bug: Control: Agilent ICF GC - Sampler method parameters not uploaded to GC correctly in some cases.
#Fixed Bug: Control: Agilent ICF LC - Invalid Injection Location error for samplers with dual tray.
#Fixed Bug: Control: Antec Decade Elite - Hardware status dialog refreshed at Instrument window opening.
#Fixed Bug: Control: Antec Decade Elite - Pulse mode, incorrect warnings for pulse time t2 - t5 settings.
#Fixed Bug: Control: CTC PAL3 ICF driver - not functional auxiliary signals.
#Fixed Bug: Control: CTC PAL3 in sequence mode sequence failed in case of more than 50 injections were scheduled.
#Fixed Bug: Control: CTC-PAL nonfunctional HS-inj.cyx cycle from update in version 8.2.0 restored to previously used version.
#Fixed Bug: Control: CTC-PAL3 problems with vial addressing for multiple tray holders.
#Fixed Bug: Control: HTA HT300A sampler wrong (default) configuration values printed within method report.
#Fixed Bug: Control: HTA HT4000L possible crash during sequence caused by memory leak in the control module.
#Fixed Bug: Control: Microsaic MS detector - wrong signal sample rate under some settings.
#Fixed Bug: Control: Sedere ELSD detector - possible wrong start synchronisation in case temperature program is used.
#Fixed Bug: Control: Shimadzu AOC-20 wrong injection volume limits control for 0,5 ul syringe.
#Fixed Bug: Control: Shimadzu LC-10/20 system error in performing Init-Standby mode.
#Fixed Bug: Control: Shodex RI-500 possible spikes in signal at sampling period 1 sec or higher.
#Fixed Bug: Acquisition: Wrong formatting for the %w variable (Monday shown as 02, should be 1).
#Fixed Bug: Audit Trail: Clarity in non-English localization since version 8.1 was not able to correctly display audit trails generated prior to Clarity 8.0.
#Fixed Bug: Batch: Option Complete Processing in the Batch ignored the column Close All checkboxes in the reprocessed sequence.
#Fixed Bug: Calibration: Named group was possible to use as a reference for Calculate by.
#Fixed Bug: Calibration: NORM calculation reported false check for all calibrated compounds present in the sample.
#Fixed Bug: Data Acquisition: Noise values were not updated under some circumstances (run time over 300 min).
#Fixed Bug: Data Acquisition: Wrong number of icons in Signals Toolbar (introduced in version 8.2).
#Fixed Bug: Export: Time used for time variables in File Name, Sample and Sample ID unified to the time of Start Acquisition.
#Fixed Bug: Extension EA: During Batch, Sequence or complete processing the calculation type is set wrongly to UNCAL (introduced in version 8.2).
#Fixed Bug: Extension GPC: Broad on Narrow Calibration - fixed possible failures in calculation of calibration curve.
#Fixed Bug: Extension GPC: Fixed behavior of Broad on Narrow Calibration.
#Fixed Bug: Extension GPC: GPC calibration - default settings for Normalized Height were changed to Chromatography Peak.
#Fixed Bug: Extension GPC: Possible crash due to switching of signals in overlay of multisignal chromatograms.
#Fixed Bug: Extension MS: Help on the MS Method tab not functional.
#Fixed Bug: Extension MS: Possible crash when trying to subtract 2D solvent, therefore Subtraction option is removed.
#Fixed Bug: Extension PDA: Changes in Peak Purity calculations. The reference spectrum now is peak apex in the spectrum (previously in the active signal, which may have been shifted). In case the calculated correlation is negative, it is replaced by zero (previously absolute value was used). Corrected calculation of absorbance threshold.
#Fixed Bug: Extension PDA: Peak Purity Spectra shown for Peak Start/End instead of Absorbance Threshold.
#Fixed Bug: Extension PDA: Spectral search graph not printed (introduced in version 8.2).
#Fixed Bug: GLP: GLP info in chromatogram not correctly actualized with respect to disabled signals.
#Fixed Bug: GLP: Unwanted dialog "Ask for reason of file change" during automatic recalibration from sequence (introduced in version 8.2).
#Fixed Bug: Chromatogram: Chromatogram file name in Chromatogram window not updated after Save As operation (introduced in version 8.2).
#Fixed Bug: Chromatogram: Possible crash when opening multisignal chromatograms with disabled signals in overlay.
#Fixed Bug: Chromatogram: Result Table - wrong calculation used for Centroid, Variance, Skew and Excess in case the Performance Table calculation was based on From Width at 50% height.
#Fixed Bug: Chromatogram: Result table displayed Correction Factor rounded to an integer (now shows 4 decimal).
#Fixed Bug: Chromatogram: Wrong behavior in case of auto incrementing filenames in case existing file ends with underscore followed by numbers (for example %D date).
#Fixed Bug: Method: Empty file name offered when creating calibration from Method setup (introduced in version 8.2).
#Fixed Bug: Method: Inability to link Calibration to method when parenthesis used in calibration file name.
#Fixed Bug: Other: Improved handling of command line parameters at possible timing conflicts.
#Fixed Bug: Other: Support for the old Sentinel HW key type was discontinued.
#Fixed Bug: Printing: Acquisition parameters for detectors displayed incorrect values and were thus removed from prints.
#Fixed Bug: Printing: Auxiliary signals - discrepancies with what is displayed on the screen and what is printed when fixed axis range is applied.
#Fixed Bug: Printing: Colors of Auxiliary signals is printing colors according to colors of signals.
#Fixed Bug: Printing: Chromatograms now contain information on the project within which they were acquired.
#Fixed Bug: Printing: Send Printed PDF command not functional (introduced in version 8.2).
#Fixed Bug: Sequence: Column layout modified during printing.
#Fixed Bug: System Configuration: Initial state of Digital Outputs was not stored (introduced in version 8.2).