*New: Control: Released - Interlab MAESTRO HPLC system control module has been released.
*New: Control: Testing - Apix ChromPix2 control module is available for testing.
*New: Control: Testing - EST Analytical AS120/Cobra control module is available for testing.
*New: Control: Testing - Marion Research Fixed Wavelength detector control module is available for testing.
*New: Control: Testing - Separlab Separtrix PP03 pump control module is available for testing.
*New: Control: Updated drivers - CTC-PAL3 ICF driver has been updated to version 1.5.1.0.
*New: Control: Updated drivers - ECOM Iota driver has been updated to version 2.8.0.0.
*New: Control: Updated drivers - Fuli GC 9720 Plus driver has been updated to version 1.0.1.6.
*New: Control: Updated drivers - Fuli GC 9790 Plus driver has been updated to version 1.0.0.12.
*New: Control: Updated drivers - Knauer HPLC drivers have been updated to version 8.3.0.6042.
*New: Control: Updated drivers - Young In Chromass YCChroZenGC driver has been updated to version 1.0.1.14.
*New: Control: Updated drivers - Young In Chromass YL9110 driver has been updated to version 4.0.4.15.
*New: Control: Updated drivers - Young In Chromass YL9120 driver has been updated to version 4.0.4.20.
*New: Control: Updated drivers - Young In Chromass YL9130 driver has been updated to version 4.0.2.15.
*New: Control: Updated drivers - Young In Chromass YL9150Plus driver has been updated to version 1.0.1.10.
*New: Control: Updated drivers - Young In Chromass YL9160 PDA driver has been updated to version 4.0.1.3.
*New: Control: ICF drivers - new options for Turn OFF on Instrument closing or Shutdown for selected devices (pumps, detectors, Shimadzu GC-2030, ...).
*New: Control: Dani Master TOF driver removed from installation.
*New: Control: Ecom Sapphire detector control module developed by DataApex has been replaced by control module developed by Ecom.
*New: Control: HTA HT800L sampler driver now maintained by DataApex (versioned with Clarity).
*New: Control: Microsaic MiD-4500 now displays N2 flow in the Device Monitor window.
*New: Control: Microsaic MiD-4500 now displays whether the spraychip current is healthy or not.
*New: Audit Trail: Option to open corrupted audit trails for inspection.
*New: Audit Trail: Report printing now recorded in Daily Audit Trail.
*New: Extension PDA: Added "Modified" indication of unsaved changes in Spectral Library.
*New: Chromatogram: Delete commands in Integration table were unified for easier use.
*New: Chromatogram: Method info divided to info on acquisition method and last processing method.
*New: Chromatogram: Set model function has been improved.
*New: Sequence Audit Trail: Improved logging of Sequence Options.
#Fixed Bug: Control: Agilent ICF GC control - possible crash during editing method.
#Fixed Bug: Control: Knauer LC110S pump - nonfunctional pump detection in configuration.
#Fixed Bug: Control: Knauer UVD 2.1L - crash while opening Instrument window.
#Fixed Bug: Control: Shimadzu GC-2010/2014 not giving data in Demo mode (introduced in version 8.3).
#Fixed Bug: Control: Shimadzu GC-2010/2014 not showing signal between runs in sequence.
#Fixed Bug: Control: Shimadzu GC-2010/2014 - several possible communication errors fixed.
#Fixed Bug: Audit trail: Incorrect logging of sequence stop after an error.
#Fixed Bug: Calibration cloning: wrong actualization of the %o (day in month) variable.
#Fixed Bug: Extension MS: Wrong tag and X axis position for first point in MS Spectrum graph.
#Fixed Bug: Extension PDA: PDA library stored in default location not found (introduced in 8.2 version).
#Fixed Bug: Extension PDA: Possible crash when opening PDA Window with option "Show Windows on Taskbar" disabled.
#Fixed Bug: Extension SST: Problems in printing Parameters tables in case of different parameters defined for individual compounds.
#Fixed Bug: Extension SST: SST extension, problems with display and printing of Groups.
#Fixed Bug: File Open: Possible crash when trying to open file from the HomeGroup special folder.
#Fixed Bug: Import sequence: user variables were not imported.
#Fixed Bug: Printing: Acquisition parameters for detectors displayed incorrect values and were thus removed from prints.
#Fixed Bug: Printing: Export directory in User options, Directories wrongly set by the Print to PDF selected folder.
#Fixed Bug: Printing: Too long signal label is displayed incorrectly when printed to PDF.
#Fixed Bug: Printing: Change of active window when printing from Chromatogram window.
#Fixed Bug: Printing: Incorrectly printed signal labels for chromatograms opened from default folder subfolders.
#Fixed Bug: Printing: Non-functional word wrap for audit trail printing from Audit trail window - long texts truncated (introduced in 8.3 version).
#Fixed Bug: Printing: Possible crash when Orientation - Override printer settings was used without default printer defined.
#Fixed Bug: Printing: Signal names not printed for chromatogram in Landscape orientation.
#Fixed Bug: Sequence reprocess: Link to a measured chromatogram lost when changing Sample type from Unknown to Standard.