*New: Control: Released - Analytik Jena PQ LC HPLC Pump 1125, 1130, 1132 control modules have been released.
*New: Control: Released - Interlab MAESTRO ELSD control module has been released.
*New: Control: Released - Gilson Verity 1920 control module has been released.
*New: Control: Released - Konik 560 Isocratic Pump, 560 Gradient Pump, 560 UV-Vis, 560 Oven, 560/580 DAD, AS 580, 580 Pump, 580 UV-Vis, 580 Oven, 580 RI, Q4 LCMS control modules have been released.
*New: Control: Released - Sunchrom SpectraFlow 2050 and SunTherm 2070 control modules have been released.
*New: Control: Released - Young In Chromass YCChroZen Binary Pump control module has been released.
*New: Control: Testing - Gow Mac 836 GC control module is available for testing.
*New: Control: Testing - Watrex StreamLine FC control module is available for testing.
*New: Control: Testing - Young In Chromass YL9172 RI detector and ChroZen UHPLC RI detector control modules are available for testing.
*New: Control: Updated drivers - Agilent ICF driver has been updated to version A.03.01.U1.
*New: Control: Updated drivers - Apix ChromPix2 driver has been updated to version 2.6.0.526.
*New: Control: Updated drivers - CTC PAL3 driver has been updated to version 1.8.1.
*New: Control: Updated drivers - ECOM ECD2000 driver has been updated to version 3.6.0.0.
*New: Control: Updated drivers - ECOM ECDA2000 driver has been updated to version 3.0.0.0.
*New: Control: Updated drivers - ECOM ECF2000 driver has been updated to version 1.8.0.0.
*New: Control: Updated drivers - ECOM ECO2000 driver has been updated to version 3.0.0.0.
*New: Control: Updated drivers - ECOM ECP2000 driver has been updated to version 4.0.0.0.
*New: Control: Updated drivers - Sykam S1130 driver has been updated to version 2.0.1.31.
*New: Control: Updated drivers - Sykam S5300 driver has been updated to version 2.0.0.31.
*New: Control: Updated drivers - Welch 5430 DAD driver has been updated to version 3.0.0.0.
*New: Control: Updated drivers - Young In Chromass YCChroZenAS driver has been updated to version 1.0.0.12.
*New: Control: Updated drivers - Young In Chromass YCChroZenColumn driver has been updated to version 1.0.0.8.
*New: Control: Updated drivers - Young In Chromass YCChroZenGC driver has been updated to version 1.0.1.26.
*New: Control: Updated drivers - Young In Chromass YCChroZenGCMS driver has been updated to version 1.0.1.12.
*New: Control: Updated drivers - Young In Chromass YCChroZenPump driver has been updated to version 1.0.0.15.
*New: Control: Updated drivers - Young In Chromass YCChroZenUVD driver has been updated to version 1.0.0.16.
*New: Control: Updated drivers - Young In Chromass YL9120 has been updated to version 4.0.4.24.
*New: Control: Agilent ICF control modules - New option to use Custom module names.
*New: Control: Agilent ICF Fraction Collector - Collected fractions are highlighted in the measured chromatogram, with detailed info displayed in the additional Fraction Collector Compound Table.
*New: Control: Hitachi LaChrom Elite - Driver discontinued (not compatible with supported Windows versions).
*New: Control: Interlab Omega UV and FLD detector - Events marking wavelength change during the time program in the chromatogram are added.
*New: Control: PG Instruments HPLC system (development state) - Driver discontinued.
*New: Control: SSI Pumps and SSI Next Gen Pump - Will now distinguish the High and Low Pressure limit error.
*New: Calibration: When adding peaks from multisignal chromatogram with the option On Active Signal the default names of compounds or groups will be constructed as "Retention Time" + "Signal Name".
*New: Clarity: Software registration now needs to be confirmed by link send via e-mail.
*New: Clarity: The Clarity software is compatible with Windows 11.
*New: Clarity: The limit is implemented for the minimum size of the selected windows and subwindows (when using a splitter).
*New: Export Data: Export Summary Table exports according to the Table Headers checkbox settings.
*New: Export Data: Export to Excel is now in a new format *.xlsx. (Excel 2007 and newer must be installed on the PC.) Export to older versions of Excel (prior to 2007) has been discontinued.
*New: File Open dialogue: Filtering and sorting is improved.
*New: File Open dialogue: Handling of large data sets is now faster.
*New: Chromatogram File Open dialogue: Multiselection of chromatogram automatically opens chromatograms in an overlay. Using the arrow in the Open button it is possible to use an alternative option Browse Selected Chromatograms.
*New: Chromatogram File Open dialogue: New three-state checkbox All Signals now simplifies the selection of signals when opening multisignal chromatogram(s).
*New: Chromatogram File Open dialogue: Open Chromatogram Sequentially renamed to Browse Through Chromatograms.
*New: Chromatogram File Open dialogue: User can now more easily select how to open selected chromatogram/s (Overlay/Replace opened one/Browse only selected ones).
*New: Chromatogram: All Signals Result Table now can be exported using Export Data dialog.
*New: Chromatogram: Improved memory handling of method versions history during chromatogram creation.
*New: MS Extension: Now quantification signal is constructed for every m/z used for quantification, compounds that have very similar or the same retention time, but which are quantified on different m/z are calculated independently.
*New: MS extension: Peak selection in MS method and calibration is now extended with the Best Match option.
*New: OQ Wizard: Amended report styles to use a footer for Results and Signatures.
*New: Other: TeamViewer QS (tool for online support) is now accessible in the Help menu in the Main window via a link that ensures that you will always use the newest version.
*New: Print: Footer can now be set in Report Setup.
*New: Single Analysis: Print settings are now easily accessible from the Post Run Settings tab.
*New: SST extension: Now supports SST method versions.
*New: User Accounts: New option to duplicate existing user settings when creating a new user.
*New: Variable Parameters: Added support for formatting fixed number of digits in selected %variables (%v, %V, %i, %I, %c, %L, %l). Previously such formatting was used only in automatically added %(n)v and %(n)i variables in File Name.
#Fixed Bug: Control: Agilent 6890 GC - Parameters for AS were not printed in the method report.
#Fixed Bug: Control: Agilent ICF control - Memory leaks due to not emptying auxiliary signals buffers (introduced in version 8.6.0).
#Fixed Bug: Control: Agilent ICF GC control - Support for dual injectors: missing check for back injector vial position validity before acquisition.
#Fixed Bug: Control: Antec Decade Elite - Faulty check for pulse duration t5 in Pulse mode (2,0s was accepted but the maximum value is 1.99s). The station stayed in Waiting for the remaining data from the hardware.
#Fixed Bug: Control: Colibrick - Possible missed start when the Synchronise with Digital Input option was used on Colibrick shared between multiple instruments.
#Fixed Bug: Control: Rheodyne LabPro validation of 10 position valve did not function properly.
#Fixed Bug: Control: Shimadzu GC2010/2014 - Method - Sending of Time Table and Pre Run Table to the device failed.
#Fixed Bug: Control: Spark Symbiosis - Two instruments of the same type (e.g. 2x HPD) did not communicate.
#Fixed Bug: Audit Trail: Circumstances of occurrence and User name were not displayed in a log of confirmation to System messages.
#Fixed Bug: Batch: Incorrect integration table applied in multisignal chromatograms with disabled signals in the method.
#Fixed Bug: File Open dialog: Selected sorting was changed after each restart of Clarity.
#Fixed Bug: Import Chromatogram: Crash during import of *.cdf file with the unexpected source data format.
#Fixed Bug: Method Setup: Created Date after Save As the operation was incorrect in some circumstances.
#Fixed Bug: PDA Extension print: Found spectra were not printed in Library Search Results, Spectra graphs since version 7.4.
#Fixed Bug: PDA Window, Spectral View: Spectra selected from spectral Library to overlay was not printed.
#Fixed Bug: Print report: Signals colors could differ on screen and in Print Preview/Print.
#Fixed Bug: Print to PDF: Page borders not used correctly.
#Fixed Bug: Print: Problems with printing multi-line table headers (dependent on used font size).
#Fixed Bug: Sequence: Vial numbers were not printed for the not measured sequence in case the print preview was invoked from Report Setup Window.
#Fixed Bug: SST extension: Possible problems during Print from Post Run.