*New: Control: Released - Recipe EC6000 control module has been released.
*New: Control: Released - Young In Chromass ChroZen HPLC RID-E control module has been released.
*New: Control: Testing - Axcend Focus LC control module is available for testing.
*New: Control: Testing - CMP Scientific ECE-001 control module is available for testing.
*New: Control: Updated drivers - Agilent ICF driver has been updated to version A.03.02.
*New: Control: Updated drivers - Apix ChromPix2 driver has been updated to version 2.7.0.545.
*New: Control: Updated drivers - Sykam S150 driver has been updated to version 3.0.0.7.
*New: Control: Updated drivers - Vici Valco FTP200 driver has been updated to version 1.2.0.6.
*New: Control: Updated drivers - Vici Valco TCD3 driver has been updated to version 1.0.0.12.
*New: Control: Updated drivers - Young In Chromass YL9110 driver has been updated to version 4.0.4.18.
*New: Control: CB11 - Removed from installation.
*New: Control: Colibrick - An option to offset data is available in the Colibrick setup.
*New: Control: Colibrick - Print format of method parameters is improved.
*New: Control: Colibrick, U-PAD2, and Zebrick now use WinUSB driver from Microsoft instead of driver from Silicon Laboratories Inc.
*New: Control: Control modules written in UNI-Ruby now support User Units setting as defined by the user.
*New: Control: INT5 - Removed from installation.
*New: Control: Recipe EC6000 detector - New option to start acquisition using the AutoZero digital input.
*New: Calibration: New function "Filter Not Used Compounds" allows to show only compounds used on the selected signal.
*New: Clarity: "nA" (nanoAmpere) is now available in Current units.
*New: Clarity: Integration Algorithm has been updated to 8.0 Rev.3.
*New: Export Data: Export to text file with .csv suffix is now available, the data format corresponds to the settings in the Export Data dialog.
*New: Chromatogram File Open dialog: Open button now has a dynamic label, the user can easier distinguish whether chromatogram(s) will be opened in the overlay or not.
*New: Chromatogram: New columns (hidden by default) are present in the Result tables "Start Value (Signal)" and "End Value (Signal)" useful for calculating Peak to Valey Ratio in User Columns.
*New: PDA Extension: The Peak Purity based on the Pearson correlation coefficient now uses an improved method of rescaling to the resulting 0-1000 interval.
#Fixed Bug: Control: Agilent ICF - Fixed issue where ICF wasn't uninstalled according to settings.
#Fixed Bug: Control: Agilent ICF LC - Acquired chromatogram could be replaced by a short chromatogram or chromatogram with no data as a result of false start detection under rare conditions.
#Fixed Bug: Control: Fraction collectors - Coloring of a fraction didn't match the real fraction end.
#Fixed Bug: Control: Microsaic MiD 4000 - A spectrum of incorrect length could be received when using methods with different settings in sequence.
#Fixed Bug: Audit Trail: Print preview caused resizing of table rows.
#Fixed Bug: Clarity: "Ask for reason of file change" is now invoked only once while performing Batch operations, reason is filled for all affected files.
#Fixed Bug: Clarity: Fixed possible crash when HW key was removed while Clarity was in use.
#Fixed Bug: Clarity: Maximizing the Instrument window in Tablet Mode could hide other windows without a possibility of displaying them.
#Fixed Bug: File Open Dialog: Dialog was always opened in the default folder, now the last opened folder is loaded instead.
#Fixed Bug: File Open dialog: Focus wasn't in File Name field, therefore, it wasn't posibble to type immidiately.
#Fixed Bug: GPC extension: Show Value Units was not functional for the molecular weight averages columns, now displaying "Da" as units.
#Fixed Bug: Chromatogram: Fixed possible crash during merge chromatograms operation due to duplicate signal names.
#Fixed Bug: Chromatogram: Peak apex could be detected in a point next to the actual highest point under rare conditions.
#Fixed Bug: Chromatogram: The reason for not calculating amounts was only displayed in the Results tab, now it is displayed in the All Signals Results tab as well.
#Fixed Bug: Chromatogram: Using Print to PDF deleted Presets in Import Chromatogram.
#Fixed Bug: Method Setup: Forced method adaptation could lead to disabling of auxiliary signals.
#Fixed Bug: MS Extension: Fixed issue where graphs of MS chromatograms were not displayed corretly in report when MS Offesting was used.
#Fixed Bug: PDA Extension: Add to Library exported spectrum from the last point before selection, now spectrum from the closest point to the selection is exported.
#Fixed Bug: PDA Extension: PDA Window wouldn't get hidden during Autolock.
#Fixed Bug: Sequence: An attempt to open single chromatogram from a row with multiple measured chromatograms resulted in all of them being opened.