Search

Displaying 2651 - 2700 of 3173

CLARITY RELEASE NOTES

  1. service release (not any feature changes)
  2. service release (not any feature changes)
  3. *New: AS Control - Spark Holland Triathlon - new tab with graphical tray display was added to Method Setup - AS Control dialog *New: Driver for MultiCOM, an USB-RS232 converter device, has is now…
  4. service release for compatibility with Clarity (not any feature changes)
  5. *New: LC Control: new control module for Hitachi - L-6200 pump - available for testing *New: LC Control: Shimadzu LC-10/20 system control - support for SPD-M20A - available for testing *New: LC…
  6. service release for compatibility with Clarity (not any feature changes)
  7. *New: DET: New control module for Softa ELSD detectors - available for testing *New: LC Control: New control modules for Young-Lin 9100 HPLC (developed by Young-LIN) *New: GC Control: New control…
  8. service release for compatibility with Clarity (not any feature changes)
  9. *New: Young Lin drivers were updated CswYL6100.dll 1.0.0.2, CswYL9120.dll 1.0.0.4 , CswYL9160.dll 1.0.0.3 *New: AS Control: Shimadzu SIL-20Axr/ACxr available for testing *New: LC Control: Shimadzu LC…
  10. service release for compatibility with Clarity (not any feature changes)
  11. ------------- Main changes in the version 2.7 comparing to the version 2.6 ------------ Control Modules: *New: Control modules Hitachi LaChrom Elite (L2100/2130 pump, L2200 autosampler, L2300 Column…
  12. ------------- Main changes in the version 2.7 comparing to the version 2.6 ------------ Installation: *New: New installer, it better controls the installation and uninstallation process of Clarity…
  13. ------------- Main changes in the version 2.8 comparing to the version 2.7 ------------ *New: Launch Manager - a utility for easy starting of Clarity with different configurations and user…
  14. ------------- Main changes in the version 2.8 comparing to the version 2.7 ------------ *New: Clarity Lite is compatible with Microsoft Windows 7. #Fixed Bug: Export Results: different format of…
  15. *New: Control LC: Young Lin updated drivers YL6100 version 2.0.0.5, YL9110, YL9120, YL9130, YL9160, YL9170, YL9180 version 2.0.0.3*New: Hardware: updated INT9 driver now supports 64 bit Windows*New:…
  16. *New: Hardware: updated INT9 driver now supports 64 bit Windows#Fixed Bug: Sequence - the  seq_import_append command line parameter worked incorrectly for certain columns#Fixed Bug: The…
  17. *New: Control: Updated drivers for  YL6100 GC  version 2.0.0.6,  YL9110 Pump.  YL9160 DAD, YL9170 RI   version 2.0.0.4#Fixed Bug: LC Control: HTA HT300A - nonfunctional Tray type detection.#Fixed Bug…
  18. --- service update - no changes in features ---
  19. #Fixed Bug: Clarity SDK could cause computer memory overwriting in control modules developed by external companies (bug introduced in version 2.8.3).  
  20. --- service update - no changes in features ---
  21. Control Modules:*New: DET Control: Sedere ELSD detector driver is now available for testing.*New: GC Control: Agilent GC 7890 control module is now available for testing.*New: AS Control: Agilent…
  22. Chromatogram:*New: Exporting data in Excel format*New: Items in any column of the Result Table can be displayed as peak tag in the chromatogram graph.   *New: Possibility to highlight peaks and…
  23. *New: GC Control: Shimadzu GC 201x - APC/AFC control .*New: AS Control: Spark Alias with user program (Beta version) developed by DataApex.*New: AS Control: HTA HT800L updated driver ver. 1.5.0.0.*…
  24. #Fixed Bug: Problem with remembering the configuration of U-PAD2 in Clarity Lite.#Fixed Bug: Crash in the Sequence Table upon attempt to move up the edited line.#Fixed Bug: Warning when starting…
  25. *New: LC Control: Agilent 1200 - control module now support G1315C DAD and G1321B FLD detectors*New: Updated drivers for MasterGC 1.4.0.26 and new driver for Master DHS  dynamic headspace sampler 1.0…
  26. #Fixed Bug: Report Setup - the instrument method has not been printed in case the order of print sections was changed.
  27. *New: GC Control: Agilent 7890 control module is available in Clarity.*New: AS Control: Spark Holland Alias driver from DataApex is available in Clarity. Compared to the driver from Knauer it enables…
  28. #Fixed Bug: Print from Overlay, the Active Chromatogram Only checkbox printed the first opened chromatogram instead of the active chromatogram.#Fixed Bug: The command line parameter "export_results"…
  29. *New: Updated drivers version 3.0.3.3033 for Knauer instruments.*New: Updated driver version 3.0.0.2 for Young Lin  YL 913x.*New: GC Control: Shimadzu GC 201x with APC/AFC control is now released.*…
  30. *New: LC Control: GL Sciences LC800 HPLC system has been released.*New: LC Control: Spark SPH 1240 pumps control module is available for testing.*New: LC Control: New control drivers available for…
  31. --- service update - no changes in features ---
  32. *New: Hardware: new external A/D Converter Colibrick.*New: Available Control Modules – indication of available, but not installed modules was added.  *New: Calibration - new peak names are created…
  33. *New: The Windows 2000 are no longer supported in Clarity version 4.0 and higher.  Older versions are still available for downloads. *New: Command Chromatogram - Baseline - Allow Crossing enables the…
  34. *New: LC Control: New control module Young Lin YL9800 HPLC.*New: Updated U-PAD2 drivers (signed by Microsoft).#Fixed Bug: Import CDF files - incorrect signal ranges (introduced in 4.0.0).#Fixed Bug:…
  35. *New: Updated U-PAD2 drivers (signed by Microsoft).#Fixed Bug: Import CDF files - incorrect signal ranges (introduced in 4.0.0).
  36. *New: Control AS: New HTA HT3x00A control module governing HT3000A, HT3100A and HT3200A  autosamplers is now available for testing.*New: DET Control: Grace Alltech 3300 ELSD detector control module…
  37. *New: Amended  Registration window#Fixed Bug: Chromatogram comments - only first line was printed (introduced in 4.0.0).#Fixed Bug: Possible crash in System Configuration dialog, during addition of…
  38. 4.0.3 - 4.12.2012*New: Clarity supports Windows 8.*New: Control AS: Bar Code Reader support - Vial Barcode (variable %f) in Chromatogram file name and related fields.*New: Control AS: Cetac ASX-8000…
  39. *New: Clarity Lite support Windows 8.*New: HW key Rockey4 ND dongle is now supported on Windows 8.*New: Sequence: Limit for maximum number of injections in Sequence (adjustable in User Options).#…
  40. *New: Clarity is compatible with Microsoft Windows 8.*New: Control AS: HTA HT 3x00A autosampler control module has been released.*New: Control DET: Shodex RI-101, RI-102 and RI-104 detector control…
  41. *New: Clarity is compatible with Microsoft Windows 8.#Fixed Bug: Tangent Slope Ratio not functional.#Fixed Bug: Wrong order of warning messages when creating New method.#Fixed Bug: Calibration -…
  42. *New: Extension MS: Evaluation module - development state.*New: Localization - option to switch Clarity to different Languages (Spanish, French, Russian, Chinese). German localization can be…
  43. *New: Localization - option to switch Clarity to different Languages (Spanish, French, Russian, Chinese). German localization can be purchased separately from Techlab company.*New: Calibration:…
  44. *New: Clarity2Go - improved "Clarity2Go Configuration" window.*New: Clarity2Go - support for proxy server setting in Clarity2Go Configuration / Advanced dialog.*New: Control AS: CTC-PAL  GC_Inj and…
  45. #Fixed bug: Acquisition: In start-restart mode the autostop time was not reset at restart and the next acquisition ended prematurely. Affected only some detectors.#Fixed bug: Multiple ISTD:…
  46. *New: Control: Spark ACE and HPD control modules are now part of the Symbiosys control module.*New: Audit Trail: Some errors were not correctly recorded in Daily Audit Trail.*New: Calibration:  the…
  47. *New: Calibration:  the  "Is ISTD" and "Use ISTD from" list-boxes are now available also on the Compound tab.*New: Clarity now supports 32 signals in chromatogram.*New: Command line parameters: new…
  48. *New: Control: Advion Expression CMS MS detector released.*New: Control: Eksigent - UltraLC 100/110 - HPLC System has been released.*New: Control: Spark Holland Symbiosis control module (Alias, ACE,…
  49. *New: Calibration: Named Groups defined in the Calibration will be displayed in the Chromatogram - Result table below the Total Row. One compound could be present in several named groups. Not…
  50. *New: Control: Dani Master SHS AS driver updated to version 1.0.4.0.*New: Control: Ecom drivers ECD2000, ECP2000 and ECO2000 updated to version 1.2.0.0.*New: Control: Chromophor Chromopeak 2010 pump…