Search
Displaying 1751 - 1800 of 3173
DOWNLOADS
- Sykam S5200 (AS) (Documentation - Manuals)
- Techlab K-7 (Thermo) (Documentation - Manuals)
- Teledyne Foxy 200 (Documentation - Manuals)
- Teledyne Foxy Jr. (Documentation - Manuals)
- Teledyne Foxy R1, R2 (Documentation - Manuals)
- UNI Ruby (Documentation - Clarity Datasheets)
- UNI Ruby Development (Documentation - Presentations)
- U-PAD A/D converter (Documentation - Manuals)
- U-PAD2 A/D converter (Documentation - Manuals)
- U-PAD2 driver, 64k Windows Vista, 7, 8 and 10 compatible (Software - Others)
- Upchurch (Valves) (Documentation - Manuals)
- User Columns - Overview (Documentation - Tutorials)
- Using Dragon II DHA© with Clarity (Documentation - Clarity Datasheets)
- Using Silex LAN-USB adapter with Colibrick A/D converter and Clarity (Documentation - Clarity Datasheets)
- Using SIMDIS Expert® 9 (Separation Systems) with Clarity (Documentation - Clarity Datasheets)
- Using Validat 5 (iCD) with Clarity (Documentation - Clarity Datasheets)
- Valco valve as autosampler (Documentation - Manuals)
- Validation protocol (For Distributors - Distributor resources)
- VICI Valco (Valves) (Documentation - Manuals)
- Watrex CTC 100 (Thermo) (Documentation - Manuals)
- Wayeal Control Module Installer (Software - Others)Control module for FLD3200 fluorescence detector.Compatible with Clarity version 10.0+
- Windows desktop wallpapers (Documentation - General Datasheets)A pack of nice Microsoft Windows desktop wallpapers made by DataApex. Images are provided in various resolutions.
- Working with multisignal chromatograms (Documentation - Tutorials)
- YoungIn Chromass YL9140 FLD (Documentation - Manuals)
- Zebrick D/A and D/f converter (Documentation - Manuals)
FAQ
- The "No Data received for 10 sec" or "No data from Acquisition..." messages mean what they say, no data were received from a detector or A/D converter (Colibrick, etc.) for a certain time.…
- Yes, Clarity can be connected to any LIMS by importing/exporting text files. Results can be exported in various formats to the LIMS, and the sample info can be imported from a TXT file into Clarity…
- Yes, it can. However, the philosophy of use is slightly different. The peak areas of a selected group of peaks are summed, and the group can be named and calibrated as a single compound. Please refer…
- There may be multiple different reasons. Please check the detailed status in the Instrument window and Device Monitor.Waiting for Injection - indicates parameters for injection were sent to the…
- Dani Master GC In case your Master GC has an older firmware that supports an older version of Clarity than you have installed it is possible to use older drivers in newer Clarity (up to 8.1).…
- Yes, you will need to purchase an upgrade if the major version of the software has changed and if you are not eligible for a free upgrade as you have exceeded the one-year free software upgrade…
- If you have bought an extension or control module license, you will get a new user code for the latest SW version and have to use the version compatible with the user code (if you have it, there is…
- Bar code scanner support is implemented within a few autosampler control modules (Spark Integrity, HTA HT4000, …). The read bar code will be available as the %f variable for use in SampleID, Sample,…
- Clarity is a 32-bit process, which means it can use the max of 2GB RAM, but if you use more than one demanding instrument, it can still be beneficial to have 8 GB RAM, so the PC has enough RAM left…
- Most chromatography systems use a proprietary data format (the main reason is the belief that it ensures data integrity for GLP-related requirements). To open and process such chromatograms in…
- Multiposition valves are frequently used as a simple fraction collector for preparative purposes.Knauer provides dedicated control modules for multiposition valve-based fraction collectors…
- An upgrade to the new major Clarity version (change in the first number before the dot) is paid and requires a new user code. Please refer to your price list under p/n C500 (C400/C591). All minor…
- The peak detection algorithm used in FC-GP can be explained using the figure below. The red color is the signal, and the blue color is the derivative of the signal (basically a slope at that moment…
- In Clarity, up to 4 independent configurations can be set up - one on each available Instrument with an independent time-base. Up to 32 signals/channels can be acquired on one Instrument. The…
- If your PC and chromatograph are connected directly via LAN and autodetect is not possible, continue with the following procedure:You need a cross-over ethernet cable (a straight-through cable is not…
- A Connect key is needed to activate communication between Clarity and Nexera control module. The Connect key (text file) will be generated by Shimadzu support upon providing the following…
- A user needs to fill out the "Registration of a university package" form that is available on our website. A description of the registration procedure is a part of Clarity Offline delivery.
- The Clarity software license is fixed on the HW key. The software itself could be installed freely on different computers, but without the HW key, it will not start.To move Clarity to a new PC,…
- If it is required to print the audit trail of the method (*.met) file, it is necessary to perform this print directly from the Method Setup dialog, where the correct method is opened. Report style…
- State of Clarity Instrument can be read by other software using a built-in DDE server. For more information, please see the datasheet D070 DDE synchronization of Clarity with other programs.
- During acquisition, data are stored in the temporary directory (...\TMP\ $ch1run.raw file ). The data are stored from memory to disk in approximately 1 min intervals. In case the Clarity crashes/…
- The sample rate needs to be set to provide enough points to describe the peaks of interest adequately. It is recommended that at least 30 points be reached per the narrowest peak width. The default…
- LAN communicationGeneral issuesFor LAN communication, one of the 1100/1200 modules must be equipped with a LAN communication card inserted in the MIO slot on the backside of the module (do not…
- It is possible to schedule a task that will run Clarity with defined parameters automatically starting a sequence. Proceed as follows:Prepare a batch file (clarity.bat) to perform the required tasks…
- If you purchase a software upgrade for your Clarity or Clarity Lite Software license, you will get a free upgrade for your associated free Clarity Offline. You only need to list the Clarity Offline S…